close
Mobil Uygulamamızı ücretsiz indirin Anlık mesajlaşma özelliği ile Mesajlaşma şu an yayında, hemen kullanmaya başla!
Tüm Menü

Kindly provide us with your quotation to cover the supply of the materials specified as per the following and attachment:- RFQ 24-1092 ACC LV SWGR Spare Parts-2-APZ • Validity of your offer. • Delivery Period(production date + shipping date) *Datasheet. • Terms of payment: • Shipping details • Shipment: CFR-Aqaba/Jordan Seaport or CPT Air fright Amman/ Jordan . • Country of Origin ; Country of Shipment

Please kindly recommend the top 3 manufacturers of medium voltage and high voltage switchgear 66 kV SWITCHGEAR HV system consists of: • Withdrawable circuit breaker pc 1 • Earthing switch pcs 2 • Voltage transformer pcs 3 • Current transformer pcs 3 • Surge arrester pc 3 • Joining material set 1 • Steel construction set 1 The 66 kV switchgear system is placed indoor, in a separate room. It comprises of a withdrawable live tank circuit breaker, including both breaking and disconnecting function, together with instrument transformers. 72,5kV THREE‐PHSE SF6 CIRCUIT BREAKER, 3P OPERATION Brief performance description: • Installation: Outdoor/Indoor • Type: Withdrawable, disconnecting function SF6 • Power frequency: 50 Hz • Rated voltage: 72,5 kV • Rated current: 2000 A • Rated breaking circuit: 25 kA • Operation type: 3pole 72,5kV SUBSTATION EARTH SWITCH Brief performance description: • Installation: Outdoor/Indoor • Power frequency: 50 Hz • Rated voltage: 72,5 kV • Rated current: 2000 A • Operating mechanism: Manual or motor Medium voltage switchgear panel used for connection of generators, generator synchronisation, power supply of station service system, voltage and current metering and connection to common step-up transformer outgoing for evacuation of generated power to grid. Equipment: Metal-enclosed, modular MV switchgear, for indoor installation, with routine tests, without type, factory-acceptance and special tests, made up of modular units with main characteristics listed below. Configuration • According to SLD Main technical data: • Nominal system voltage: 10 kV • Rated voltage: 24 kV@ 1000 m a.s.l. • short-duration power-frequency withstand voltage: 50/60 kV @ 1000 m a.s.l. Lightning impulse withstand voltage 125/145 kV @ 1000 m a.s.l. • Rated frequency: 50 Hz • Rated current, busbar: 630 A • Short-circuit withstand current: 25 kA (1 s) • Busbar insulation: AIS • Circuit breaker type: Vacuum, E2, M2 • Auxiliary voltage: DC 110 V, DC 24 V, AC 230 V • Installation Ind I would like communication by email

to find manyfactory how is produce 14.2.1 Surge Arresters. Nominal voltage for surge arresters is 10 [kV] silicon insulators and fuse

I need ese la manufacturers Early streaming emissions lightning arrestor

Siemens 3EL2 102-2PJ31-4XA1 3EX5 030-0A Surge Counter these 2 items 3 PCs Each Could you supply? HEre is 3,00 PC C1B49004920003 3EX5 030-0A Surge Counter

Item Designation Qty 1 3 Phase Load Break Switch(Pulse voltage 195kV,25kV peak short circuit current, rated current 630A, 50Hz) 2 18 Droup Out Fuse Link 33KV,Minimum contour distance of 900 mm. Minimum insulation distance 430 mm. Maximum voltage under rain 70 kV. Shock impulse (kV peak), with solid contact = 200 kV, Bias voltage 230 kV 27 55 Surger arrester 10 kA , metal oxide, heavy load class. Joslyn of the ZHP type. 33 kV systems, MCOV 44 kV, Residual voltage at 10 kA, current pulse of 8/20 micro-seconds, adulation distance to 100 kV 15

i would like to find Surger Arrester and Instrument Transformer for High Voltage in Turkey Could you advice some provider can do it?

Destek Whatsapp Başa Dön