Who are making chillers and AIR COOLING systems Parameters of the supplied heat exchange unit: Capacity not less than 1700 kW. Water flow rate not less than 80 l/year, Dimensions: length - not more than 6300 mm, width - not more than 2500 mm, Height - not more than 5000 mm. (including noise suppression height),

want to buy air conditioners from you if possible. we need 13 items. If it is possible, I would like your representative to contact me to ask some detailed information. Thank you in advance

we are Georgia Tbilisi Base company and interested in VRF system units:

We are tech company operating in Tbilisi, Georgia since 2010, participating in big and medium size tenders and retail as well and searching for professional and trustable company for long term partnership who can provide and supply, heating, ventilation, air conditioner and all other types of building systems.

Precision conditioner 3 pieces maximum dimensions: Indoor unit: 2495*1777*900 mm (height x width x depth); • Indoor unit: with at least 2 (two) compressors; • Outdoor unit: with at least 2 (two) fans; • Air flow: from top to bottom; • Cooling capacity (Total): not less than 58 kW; • Effective cooling capacity (Net sensible cooling capacity): not less than 53.5 kW; • Air flow: internal block not less than 14,000 cubic meters per hour; external block not less than 12,000 cubic meters per hour; • Ambient temperature range (for maximum power value) -15°C ... 40°C; • EU 4 class air filters; • used refrigerant R410A; • Ability to control and monitor the main parameters of the air conditioner; Communication interface/protocols: Ethernet, TCP/IP, HTTP, SNMP, SMTP; (at least 1 module to monitor all three air conditioners)

I search Ventilation Equipments manufactures , air conditioner and hvac systems

Do you install geothermal heat pump systems? I am looking for a company that can provide full service including bore hole and installation of heat exchange system here in the Republic of Georgia.

We are looking for suppliers for our current project and we need: HVAC pipes Air ducts, Accessories Insulation Valves

We are only interested in cooperating with manufacturing companies. We distribute in all regions of Georgia.